This ventilator delivers outstanding performance in operating rooms, ICU wards and emergency departments. It is designed to assist or replace spontaneous breathing for adult, pediatric and neonatal patients. With 25‑years of market‑driven ventilator expertise, we are professional and reliable to meet all your ventilation requirements. Featuring flexible configurations, superior quality and highly competitive pricing, the S1100 has quickly become a market‑preferred model.

Superstar S1100 ICU Ventilator Specifications

Ventilation Modes

IPPV, V‑A/C, P‑AC, P‑SIMV, V‑SIMV, PCV, PSV, SPONT/CPAP, PRVC (optional), APRV (optional), DuoLevel (optional), SIGH, MANU

Ventilator Parameters

  • Tidal Volume (Vt): 0.20‑2000 mL

  • Frequency (Freq): 1‑100 bpm

  • Oxygen Concentration: 21%‑100%

  • I:E Ratio: 4:1 ~ 1:8

  • PEEP: 0 cmH₂O‑40 cmH₂O

  • Pressure Limit: 20 cmH₂O‑100 cmH₂O

  • Pressure Trigger Sensitivity (Pt): −20 cmH₂O‑0 cmH₂O (based on PEEP)

  • Flow Trigger Sensitivity (Ft): 0.5‑30 cmH₂O

  • Sigh: 0 (Off), 1/100‑5/100 breaths

  • Apnea Ventilation: Off, 5‑60 s

Monitored Parameters

  • Frequency (Freq): 0‑100 bpm

  • Tidal Volume (Vt): 0‑2500 mL

  • Minute Ventilation: 0‑99 L/min

  • Airway Pressure: 0‑100 cmH₂O

  • Dynamic Compliance Monitoring: 1‑1000 mL/cmH₂O

  • Oxygen Concentration: 15%‑100%

Alarms & Protections

  • AC power failure alarm

  • Power loss or disconnection alarm

  • Low‑voltage alarm for built‑in backup battery: ≤11.3±0.3 V

  • No‑tidal‑volume alarm: no tidal volume detected for 6 seconds

  • High minute‑ventilation alarm: 5‑99 L/min

  • Low minute‑ventilation alarm: 1‑30 L/min

  • High airway‑pressure alarm: 20‑100 cmH₂O

  • Low airway‑pressure alarm: 0‑20 cmH₂O

  • High oxygen‑concentration alarm: 19%‑100%

  • Low oxygen‑concentration alarm: 18%‑99%

  • Continuous pressure alarm: pressure stays at (PEEP+1.5 cmH₂O) for 16 seconds

  • Apnea alarm: 5‑60 s

  • Fan failure: on‑screen indication

  • Oxygen shortage: on‑screen indication

  • Max pressure limit: <12.5 kPa

Operating Conditions

  • Gas Source: O₂, Air

  • Gas Pressure: 280‑600 kPa

  • Voltage: 220 V±22 V

  • Power Frequency: 50 Hz±1 Hz

  • Input Power: 900 VA (with air compressor); 250 VA (without air compressor)

Waveforms

  • P‑T (Pressure‑Time)

  • F‑T (Flow‑Time)

  • P‑V Loop (Pressure‑Volume Loop)